CW Laser Technology and Continuous Beam Emission
If you would like more information or wish to request a non-binding quote, feel free to contact us at any time.
Which wavelength do you need?
Output power and fiber coupling
What's your application?*
Choose one or more, or describe your own below.
Anything else we should know?
Where can we reach you?
We use the details you provide only to process your request. More information in our privacy policy.
Thank you.
Your request has reached our sales team.
Technical Characteristics of CW Lasers
CW laser cooling and system integration
Typical Applications of CW Lasers
Further Advantages
About RGB Lasersystems
Contact RGB Laser Systems for Your Single Frequency Laser
If your application requires precise wavelength stability and narrow linewidth performance, a Single frequency laser can be specified according to your system requirements. RGB Laser Systems supports you from initial concept discussion to final configuration. Detailed technical data, integration guidance and customization options are available upon request.
Contact our engineering team to evaluate the appropriate Single frequency laser solution for spectroscopy, metrology or OEM integration. Careful parameter selection and coordinated development ensure reliable performance within your laboratory or industrial platform.
Which measurements need a continuous beam
Continuous wave operation is not merely the absence of pulsing. A whole family of measurements reads a phase, a frequency or a slowly accumulated signal, and all of them assume the light is there throughout.
- Interferometry and vibrometry. The measurement is a continuous phase record. A pulse train would sample it instead, and anything happening between pulses is lost.
- Laser Doppler velocimetry. Particles cross the measurement volume at arbitrary moments. A source that is dark half the time misses half of them.
- Raman spectroscopy. The scattered signal is weak and the detector integrates for seconds. What matters is average power on the sample, delivered at a defined wavelength.
- Fluorescence and confocal microscopy. The scan dwells on each point for microseconds and the excitation has to be present and stable for all of it.
- Triangulation and machine vision. Exposure timing is set by the camera, not by the laser, so the source has to be available whenever the sensor opens.
Continuous, modulated and pulsed are three different things
A continuous wave module can still be switched and dimmed. Analogue modulation makes the output follow a control voltage, digital modulation gates it on and off, and direct diode sources manage both at high rates because the drive current controls the output directly. This is useful for ambient light rejection, for lock-in detection and for running several sensors in the same space.
None of that makes a CW module a pulsed laser. A pulsed source concentrates energy into nanoseconds or shorter and reaches peak powers orders of magnitude above its average. That is what ablation, laser induced breakdown spectroscopy and time resolved measurements require, and no amount of gating a continuous source will produce it. Where your application needs peak power rather than stable average power, a CW module is the wrong tool and worth ruling out early.